Signaltec TPS II Single Channel Current Transducer System
- Operating temperature: -10°C to 60°C
- Supply voltage: 100-240 VAC, 50/60 Hz
- Output voltage: +15 VDC / -15 VDC
- Transducer bandwidth: 2 MHz (CT 100) to 140 kHz (CT 2000)
- Status output: Potential-free relay contacts (200 V / 2 A)
- Available transducers: CT 100, CT 200, CT 400, CT 500, CT 1000, CT 2000
- Rack housing: 19 inch, 2 HE high, 6.8 kg
- Accessories: Passive and active burden modules, cables in different lengths

The TPS II Single Channel Current Transducer System from Signaltec is a versatile and accurate solution for measuring alternating current (AC) and direct current (DC) in a wide range of applications. This transducer can safely handle large currents, making it ideal for power management, electrical testing and industrial applications where reliable current measurement is critical.
The system uses a 19-inch rack-mountable enclosure, which contains the necessary electronics as the power supply and readout of the zeroflux current transducer. The TPS II is designed for maximum accuracy and reliability, with status indicators on the front panel showing the status of the module and transducer. This provides users with immediate feedback on system operation.
The TPS II system can be powered by 100-240 VAC and provides supply voltage of +15 VDC and -15 VDC for the current sensor.
The transducer status is displayed via both LED indicators. This allows the user to easily check if the transducer is operating correctly, or if an overload or open circuit has been detected.
For systems that require higher output voltages than what passive load resistors can provide, the TPS II offers optional active plug-on load modules. These modules can generate a 7 Vrms signal at rated primary current, allowing accurate voltage measurements even at higher loads.
The TPS II supports several transducers, such as the CT 100, CT 200, CT 500 and CT 2000, all of which are capable of measuring primary currents up to 100 A, 200 A, 500 A and 2000 A, respectively. The bandwidth of these transducers ranges from 2 MHz to 140 kHz, depending on the model selected, ensuring fast response and accurate measurements in demanding applications.
The TPS II Single Channel Current Transducer System provides a complete and flexible solution for accurate current measurements, with a wide range of available current sensors. Its reliable performance and extensive capabilities make this system a valuable addition to any test setup.