DN6.44x series LXI digitizers from Spectrum
|
Spectrum DN6.44x series digitizers
The Spectrum DN6.44x series LXI digitizers are 14- and 16-bit stand-alone digitizers with a maximum sample rate of 500MS/sec. These stand-alone instruments have a built-in web server and a Gbit Ethernet connector for programming from a PC or connection in a LAN network.
Depending on the model you have up to 24 channels.
Each channel has a 512MSample memory.
In FIFO mode it is possible to simultaneously send data to PC memory or internal (optional) server, and read in new data. Data reduction is also possible with the option averager and peak detect.
Specifications of the DN6.44x series digitizers:
Model | Resolution | Single-Ended Channels | Sampling Speed | Installed |
Memory | ||||
DN6.441-12 | 16 Bit | 12 channels | 130 MS/s | 512 MS/channel |
DN6.441-16 | 16 Bit | 16 channels | 130 MS/s | 512 MS/channel |
DN6.441-20 | 16 Bit | 20 channels | 130 MS/s | 512 MS/channel |
DN6.441-24 | 16 Bit | 24 channels | 130 MS/s | 512 MS/channel |
DN6.442-12 | 16 Bit | 12 channels | 250 MS/s | 512 MS/channel |
DN6.442-16 | 16 Bit | 16 channels | 250 MS/s | 512 MS/channel |
DN6.442-20 | 16 Bit | 20 channels | 250 MS/s | 512 MS/channel |
DN6.442-24 | 16 Bit | 24 channels | 250 MS/s | 512 MS/channel |
DN6.445-12 | 14 Bit | 12 channels | 500 MS/s | 512 MS/channel |
DN6.445-16 | 14 Bit | 16 channels | 500 MS/s | 512 MS/channel |
DN6.445-20 | 14 Bit | 20 channels | 500 MS/s | 512 MS/channel |
DN6.445-24 | 14 Bit | 24 channels | 500 MS/s | 512 MS/channel |
Software DN6.44x
All Spectrum digitizers also have acquisition modes such as Multiple recording (segmented memory), Gated sampling and ABA mode (sample rate switching) for data reduction.
All digitizers come with an extensive package of software support.
Drivers for Windows and Linux operating systems (32 bit and 64 bit) are included.
The example programs and drivers for C/C++, LabVIEW (Windows), MATLAB (Windows and Linux), LabWindows/CVI, IVI, .NET, Delphi, Visual Basic and the Python are also available.
In addition, a basic license of the Spectrum software SBench 6 has been added. SBench6-Pro is optional.
For higher sample rates please refer to the DN6.22x series digitizers.
For lower sample rates please refer to the DN6.59x series digitizers.
For fewer channels please refer to the DN2.44x series digitizers.
For a complete overview of all LXI digitizers please refer to the LXI overview page.
If you would like more information, please contact one of our consultants. They will be happy to help you make the right choice.